EN
|
|
|
|
 
 print this page     send this page via email
Download Area
PDF Files
 

Pilot-operated check valves, series ERV

Series ERV pilot-operated check valves lock a cylinder in any rest position. They are intended for direct mounting in the cylinder.

 
 

Advantages  

  • Pilot-operated check function and pipe-rupture protection in one valve 
  • Optimized hydraulic pilot stage gives gentle opening 
  • Leak-free valve seats; hardened, ground and lapped  
  • Load pressure acts in the closing direction
 
 

Technical data

 

 

 

ERV 8

ERV 8-600

Nom. flow rate

Oper. pressure, dynamic

Oper. pressure, static

Area ratio

l/min

bar

bar

 

60

450

450

1:2.5/ 2.1:1

60

450

600

1:2.5/ 2.1:1

 

Note:
Main stage opens only with reduced pressure

 

Types

 

Simple p.o. check valve

 
 

Applications

 
  • Stabilizer cylinders on mobile equipment