Electronic Control Systems

Proportional Amplifier PBS-3A

  • 1-channel for proportional valves  with one solenoid
  • With integrated set value potentio- meter
Supply Output Set value PWM-frequency Data sheet
12…30 V DC 2500 mA 0…10 V 100…300 Hz PBS-3A_400-P-510101-en

Proportional Amplifier ELSK 103-*****

  • With one power output and two ON / OFF outputs
  • To drive one proportional valve and one ON / OFF directional valve
Supply Set value Output Adjustment Data sheet
12…30 V DC ON / OFF, control signal potentiometer prop. 2500 mA
on/off 3000 mA
I min, I max ELSK103_100-P-700006-en

Proportional Amplifier ELSK 103-13 and ELSK103-18

  • With one power output
  • To drive either of two proportional valves, one at a time
Supply Set value Output Adjustment Data sheet
12…30 V DC Control signal potentiometer
tipper switch
ON - 0 - JOG
2500 mA I min, I max ELSK103-13,18_100-P-700014-en

Proportional Amplifier ELSK 103-16

  • With one power output and two ON / OFF outputs
  • To drive two proportional solenoids and one ON / OFF directional valve
Supply Set value Output Adjustment Data sheet
12…30 V DC ON / OFF
50% / 100%
Left / Right

Control signal potentiometer
prop. 2500 mA
s/w 3000 mA
I min, I max ELSK103-16_100-P-700050-en

Proportional Amplifier ELSK 103-17

  • With one power output
  • To drive a proportional solenoid
Supply Set value Output Adjustment Data sheet
12…30 V DC Control signal potentiometer,
control signal change over switch
100%…50% %
2500 mA I min, I max ELSK103-17_100-P-700048-en

Proportional Amplifier ELSK 103-18

  • With one power output
  • To drive a proportional solenoid
Supply Set value Output Adjustment Data sheet
12…30 V DC ON / OFF
Left / Right
Control signal potentiometer
2500 mA I min, I max ELSK103-13,18_100-P-700014-en

Proportional Amplifier ELSK 106

  • With one power output, switch ON / OFF and ramp
  • To drive one proportional solenoid, installed for example in instrument panel
Supply Set value Output Adjustment Data sheet
12…30 V DC ON / OFF
Control signal potentiometer
2500 mA I min, I max ExSK106_100-P-700008-en

Digital 3-level Controller ELDR 105

  • With motor output for MTK../MTQ..
  • Position control
Supply Set value Output Adjustment Data sheet
12…30 V DC Potentiometer
2…5 kOhm,
control signal reversal unit
500 mA I min, I max ELDR105_100-P-700034-en

Analogue Open-loop Control Unit ELMP 150-01

  • With two power outputs that vary according to the adjustable control signals and the external control signal
  • To drive two proportional solenoids (spread density and spread width) on salt/grit spreaders
Supply Set value Output Adjustment Data sheet
12…24 V DC Spread width,
spread density,
frequency input,
analogue input for road speed
2500 mA I min, I max ELMP150-01G24-01_100-P-700021-en

Digital Closed-loop Controller EBM-152

  • Is intended for single-chamber unit with proportional liquid pump. The liquid proportion from 0% to 100% can be selected with a step switch. The controller is also intended for the application as two-chamber unit with the facility for operating with blended materials
  • Inputs: 2 analogue, 5 frequency and 4 ON/OFF outputs
  • Outputs: 4 proportional and 6 ON/OFF outputs
Supply Set value Feed back Output Adjustment Data sheet
12…28 V DC Driving speed,
spread width,
spread density
spread symmetrie
Spinner,
auger / belt,
lye pump,
spread patter
3x prop. 2.5 A
6x on / off 5.0 A
I min, I max
characteristic of regulation
EBM152070_100-P-700062-en
 

Follow us